2-wire Transmitters
|
Signal Isolators
|
Loop Powered Isolators
|
Loop Powered Indicators
|
|
|
|
|
|
|
2-wire Transmitters |
|
|
Model /
Catalog |
Parameter |
Size
HxWxD mm |
Input |
Output |
Supply |
Input / Output
Isolation |
Local Display |
Mounting |
Remarks |
|
|
|
|
|
|
|
|
|
|
|
|
SC601 |
Temperature |
80x25x85 |
Universal |
4~20 mA |
12~32 V DC
loop supply |
Yes |
|
DIN rail |
PC programmable,
latest technology |
|
TX1HM |
Temperature |
47x17 |
Pt100 |
4~20 mA / 20~4 mA |
6.2~32 V DC loop supply |
No |
LED for
Power On status |
Sensor head |
8 SPAN ranges, 4 ZERO ranges, accuracy 0.1% |
|
TX1DR |
Temperature |
80x25x85 |
Pt100 |
4~20 mA / 20~4 mA |
6.2~32 V DC loop supply |
No |
LED for
Power On status |
DIN rail |
8 SPAN ranges, 4 ZERO ranges, accuracy
0.1% |
|
TX1DR |
Temperature |
80x25x85 |
TC/mV |
4~20 mA / 20~4 mA |
6.2~32 V DC loop supply |
No |
LED for
Power On status |
DIN rail |
9 ranges for TC / mV from 10mV to 50mV |
|
TX2DR |
Temperature |
80x25x85 |
TC/mV |
4~20 mA |
10~30 V DC loop supply |
Yes |
LED for
Power On status |
DIN rail |
4 ranges for TC / mV from 5mV to 50mV |
|
TX2DR |
Temperature |
80x25x85 |
Pt100 |
4~20 mA |
12~36 V DC loop supply |
Yes |
LED for
Power On status |
DIN rail |
8 SPAN ranges, 4 ZERO ranges, accuracy
0.1% |
|
TX3DR |
Temperature |
75x45x110 |
Universal |
4~20 mA |
11~32 V DC loop supply |
Yes |
4 digit LED |
DIN rail |
Programmable, accuracy 0.1% |
|
MESO-H |
Temperature |
44x26 |
Universal |
4~20 mA |
10 V DC loop supply, 16 V DC for HART |
Yes |
|
Sensor head |
Inor make, HART Protocol |
|
TX6HM |
RH+T |
65x27.5 |
RH+T sensor module |
2 x 4~20 mA |
4.5~32 V DC loop supply |
Yes |
|
Duct mount assembly |
Programmable using programmer |
|
TX6DR |
RH+T |
120x80x55 |
RH+T sensor module |
2 x 4~20 mA |
4.5~32 V DC loop supply |
Yes |
2 x 4 digit LCD |
Field / Wall mount |
User programmable, integral or remote
sensor |
|
TX7DR |
RH+T |
80x120x55 |
RH+T sensor module |
2 x 4~20 mA |
11~32V DC loop supply |
Yes |
2 x 4 digit LED |
Field / Wall mount |
User programmable, integral or remote
sensor |
|
M5100 series |
Pressure |
See catalog |
Pressure |
4~20 mA |
10~30 V DC loop supply |
N/A |
|
Process |
Various ranges, 125 °C rated, high
accuracy |
|
TX4DR |
Frequency |
75x45x110 |
Unipolar voltage pulses |
4~20 mA |
11~32 V DC loop supply |
Yes |
4 digit LED |
DIN rail |
10 khz max, user programmable,
accuracy 0.1% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Signal Isolators |
|
|
|
Input/Output(s)/Supply
mutually isolated |
Model /
Catalog |
Size
HxWxD mm |
Input |
No of Outputs |
Output(s) |
Supply |
Display |
Mounting |
Remarks |
|
|
|
|
|
|
|
|
|
|
|
SI3P |
75x55x110 |
Voltage, Current, TC/RTD, etc |
1 |
0/4~20 mA, 0~10 V, etc |
85~265 V AC, 50/60 Hz / 17~35 V DC
|
|
DIN rail |
Most popular |
|
SI3P |
75x55x110 |
Load Cell |
1 |
0/4~20 mA, 0~10 V, etc |
85~265 V AC, 50/60 Hz / 17~35 V DC
|
|
DIN rail |
New |
|
SC301 |
80x25x85 |
0/4~20 mA |
1 |
0/4~20 mA |
20~35 V DC
|
|
DIN rail |
HART compatible |
|
SI4P |
75x45x110 |
0/4~20 mA |
2 |
0/4~20 mA |
17~35 V DC
|
|
DIN rail |
1 Kohm load, Line fault detection |
|
SI4P |
75x55x110 |
0/4~20 mA |
2 |
0/4~20 mA |
85~265 V AC, 50/60 Hz
|
|
DIN rail |
1Kohm load, Line fault detection |
|
MSI4P |
75x55x110 |
Universal |
1, 2 |
0/4~20 mA, 0~10 V, etc |
85~265 V AC, 50/60 Hz / 20~30 V DC
|
4 digit LED |
DIN rail |
Programmable, RS485/MODBUS |
|
MSI4P |
75x70x110 |
AC current/voltage |
1, 2 |
0/4~20 mA, 0~10 V, etc |
85~265 V AC, 50/60 Hz / 20~30 V DC
|
4 digit LED |
DIN rail |
Programmable, RS485/MODBUS |
|
MSI7P |
75x100x110 |
Universal |
3, 4, 5 |
0/4~20 mA, 0~10 V, etc |
85~265 V AC, 50/60 Hz / 20~35 V DC
|
2x16 LCD |
DIN rail |
Programmable, RS485/MODBUS |
|
MSI7P |
75x100x110 |
Oxygen Lambda Sensor |
1, 2 |
0/4~20 mA, 0~10 V, etc |
85~265 V AC, 50/60 Hz / 20~35 V DC
|
2x16 LCD |
DIN rail |
Programmable, RS485/MODBUS |
|
MSI7P |
75x100x110 |
Oxygen Probe (Carbon Potential) |
1, 2 |
0/4~20 mA, 0~10 V, etc |
85~265 V AC, 50/60 Hz / 20~35 V DC
|
2x16 LCD |
DIN rail |
Programmable, RS485/MODBUS |
|
VISO |
75x55x110 |
0~±10 V, 0~250hz |
1, 2 |
0~±10 V, 0~250hz |
17~35 V DC |
|
DIN rail |
For AC & DC signals |
|
FVI50 |
72x75x112 |
Unipolar or bipolar voltage pulses |
1 |
0/4~20 mA, 0~10 V, etc |
85~265 V AC, 50/60 Hz, 24 VDC,
±10% |
|
DIN rail / Wall mount |
Upto 50 KHz,
±50 mV ~ ±150 V |
|
|
|
|
|
|
|
|
|
|
Loop Powered Isolators |
|
|
Model /
Catalog |
Size
HxWxD mm |
Input |
Output |
Mounting |
Loop Drop |
Load |
Remarks |
|
a |
|
|
|
|
|
|
|
|
LPI51 |
80x25x85 |
4~20 mA |
4~20 mA |
DIN rail |
3.7V |
25~425 ohms |
Load trim potentiometer, low cost |
|
LPI61 |
80x25x85 |
4~20 mA |
4~20 mA |
DIN rail |
5V |
0~500 ohms |
No load trim required |
|
|
|
|
|
|
|
|
|
|
Loop Powered Indicators |
|
|
Model /
Catalog |
Size
HxWxD mm |
Input |
Display |
Mounting |
Loop Drop |
Remarks |
|
a |
|
|
|
|
|
|
|
SD201 |
80x120x55 |
4~20 mA |
LCD, 3.5 digit |
Field / wall mount |
1V |
0.1% accuracy, very low loop drop |
|
LC35 |
80x120x55 |
4~20 mA |
LCD, 3.5 digit |
Field / wall mount |
3V |
0.1% accuracy |
|
PLC40 |
80x120x55 |
4~20 mA |
LCD, 3.5/4.5 digit |
Field / wall mount |
4.8V |
Programmable, 0.1% accuracy, square
root function |
|
PLD40 |
80x120x55 |
4~20 mA |
LED, 4 digit |
Field / wall mount |
5V |
Programmable, 0.1% accuracy, square
root function |
|
PLD40 |
48x96x100 |
4~20 mA |
LED, 4 digit |
Panel mount |
5V |
Programmable, 0.1% accuracy, square
root function |
|
|
|
|
|
|
|
|
2-wire
Transmitters
Signal Isolators
Loop Powered
Isolators
Loop Powered
Indicators
|
|
|
a |
|