Radix RHW501 Mineral Insulated RTD Probe
Radix RHW501 Mineral Insulated RTD Probe
Radix RHW501 Mineral Insulated RTD Probe
Radix RHW501 Mineral Insulated RTD Probe
Radix RHW501 Mineral Insulated RTD Probe
Share this product with friends

Whatsapp

Telegram

Facebook

Twitter

Email

Messanger

Mineral Insulated RTD Probe

Model : RHW501

  1. Temperature ranges from -50 to 400 °C (-58 to 752ºF)
  2. Provided with various constructions
  3. Wide range of terminal heads for different applications
  4. Class A/AA accuracy
  5. Available in different diameters as per suitability to various applications
Read More...

RTD Sensors, Mineral Insulated RTD Probe | RHW501 | Radix

Similar Products

5
Industrial RTD with Protection Head |RHW201

  1. -50 to 250°C (-58 to 482°F)
  2. Non-bendable sheath
  3. Class A or Class AA accuracy conforming to IEC 60751
  4. Standard lengths are 100, 150, 200 & 300mm (3.93, 5.90, 7.87, 11.81)"
  5. Weatherproof / Flameproof / ATEX aluminium head
  6. Adjustable or fixed threaded or flanged process connection
Read More...

3
Sanitary RTD |RHS600

  1. -50 to 250°C (-58 to 482°F)
  2. Class A / AA to IEC 60751 accuracy
  3. Pt100/Pt1000, 3-wire/4-wire Simplex/Duplex/Triplex
  4. Protection IP66/67/68 (≈NEMA 4X/6/6P)
Read More...

RTS600
Transition joint Sanitary RTD Sensors |RTS600

  1. -50 to 250°C (-58 to 482°F)
  2. Class A / AA to IEC 60751 accuracy
  3. Pt100/Pt1000, 3-wire/4-wire Simplex/Duplex
  4. Roughness Value (Ra) ≤0.8 μm & ≤0.4 μm for Non-wetted and Wetted Parts Respectively
Read More...

rac243
RTD For Autoclave Validation |RAC243

  1. 0 to 150°C (32 to 302°F)
  2. Class A (1/2 DIN) accuracy
  3. Pt100, 3-wire/4-wire, Simplex/Duplex
  4. Cable length 3/5/10 m
  5. Sheath material SS316L (1.4404)
  6. Leakproof assembly
Read More...

Customers Also Viewed

1
Three Phase SCR Power Controller For Resistive Load, 35 - 200 A |TPR-3P-48xxx-H

  1. Phase angle control technology
  2. 4-20 mA / 0-10V / 2-10V / 0-5V / 1-10V control input
  3. Suitable for three phase resistive load
  4. Configuration : Three phase star without neutral / closed delta
  5. Adjustable soft-start & soft control for smooth output voltage control
Read More...

3
Sanitary RTD |RHS600

  1. -50 to 250°C (-58 to 482°F)
  2. Class A / AA to IEC 60751 accuracy
  3. Pt100/Pt1000, 3-wire/4-wire Simplex/Duplex/Triplex
  4. Protection IP66/67/68 (≈NEMA 4X/6/6P)
Read More...

rac251
RTD For Continuous Use In Autoclave |RAC251

  1. 0 to 150°C (32 to 302°F)
  2. Class AA (1/3 DIN) accuracy
  3. Pt100, 3-wire, Simplex/Duplex
  4. Cable length 5/10 m
  5. Sheath material SS316L (1.4404)
Read More...

rac244
RTD With Molded Silicon Cable |RAC244

  1. 0 to 150°C (32 to 302°F)
  2. Class AA (1/3 DIN) accuracy
  3. Pt100, 3-wire/4-wire, Simplex/Duplex
  4. Cable length 5/10 m
  5. Sheath material SS316L (1.4404)
Read More...

logo

loading